Sample of DVT Series Touch screen Viscometer

Perfect integration of touch-screen technology,fast,accurate,easy to measure viscosity.Stepless debugging,can measure super high viscosity of the sample.5-inch color touch screen can be comprehensive,visual display of a variety […]

Perfect integration of touch-screen technology,fast,accurate,easy to measure viscosity.Stepless debugging,can measure super high viscosity of the sample.5-inch color touch screen can be comprehensive,visual display of a variety of parameters and working conditions.It has many advantages,such as many measuring parameters,rich display content,convenient operation,intuitive reading,high measuring precision,stable rotational speed,strong anti-interference performance,showing the curve of shear rate and viscosity,and so on.

  Main features:

1 adopt ARM technology,built-in Linux system.The operation interface is simple and clear,through the creation of test program and data analysis,the viscosity test is carried out quickly and conveniently.

2.the viscosity test value is accurate:each measuring range is automatically calibrated by a computer,the precision is high,and the error is small;

3.display is rich:in addition to viscosity(dynamic viscosity and kinematic viscosity),there are also temperature,shear rate,shear stress,measurement value as a percentage of the full range value(graphic display,range overflow alarm,automatic scanning,Maximum measurement range,date,time and so on under current rotor speed combination.Show kinematic viscosity when density is known.

4.complete functions:timing measurement,self-built 30 groups of test programs,access to 30 groups of measurement data,real-time display of viscosity curves,printing data and curves;

5.front level:level adjustment is intuitionistic and convenient;

6.stepless speed regulation:RV1T series:0.3-100 rpm,a total of 998 rotational speeds RV2T series:0.1-200rpm,2000 revolutions

7.showing the curve of shear rate versus viscosity:the range of shear rate can be set,and displayed on the computer in real time;Curve of time-to-viscosity can also be displayed

8.Standard USB interface:insert U disk to copy data directly

9.optional Pt100 temperature probe:wide temperature range,ranging from-20℃to 300℃,and measuring precision 0.1℃;

10.Optional accessories rich:R1 rotor,temperature sensor,viscometer special thermostat bath,thermostat cup,printer,standard viscosity sample(standard silicone oil),etc.;

The measurable range is very large,ranging from 100 to 320 million MPA.

the torque of the filament,the shape of the rotor,the size of the rotational speed,and the range of viscosity measurement are the same as the imported viscometer of the same type.the measured viscosity and other data are well comparable with the imported similar instruments.

Widely used in paint,paint,cosmetics,ink,pulp,food,oil,starch,solvent adhesive,latex,biochemical products and other high viscosity industries.

Detailed technical parameters:

model LVDV-1T LVDV-2T
Control / display mode 5-inch color touch screen
speed(r/min)

 

0.3–100 infinitely variable speed , a total

of 998 speed options

0.1–200 infinitely variable speed , a total

of 2000 speed options

 

measuring range

 

Rotor 1- 4: 10-2M mPa.s

ULR: 0.6-1K

Rotor 18: 3 – 10K

Rotor 25: 480 – 1.60M

Rotor 31: 30 – 100K

Rotor 34: 20 – 200K

Rotor 1-4: 10–6M mPa.s

ULR: 0.3-6K

Rotor 18: 1.5 – 300K

Rotor 25: 240 – 4.8M

Rotor 31: 15 – 300K

Rotor 34: 30 – 600K

rotor L1 – L4 (Standard)

Enhanced ultra-low viscosity adapter ULR (optional)

Small sample adapters (rotors 18,25,31,34)(optional))

Sample dosage Rotor

1- 4: 300 – 400ml

ULR: 21ml

Rotor 18:7ml

Rotor 25: 9ml

Rotor 31: 10.5ml

Rotor 34:11ml

K = 1000; M = 1000000
measurement erro ±1% (Newtonian liquid)
repetitive error ±0.5% (Newtonian liquid)
Showing the shear response /

shear rate

standard configuration
Timing function standard configuration
Real-time display

Viscosity curve

 

Temperature-time curve

Viscosity-time curve

(The rheological curves of shear rate and viscosity can be displayed by optional data processing software)

 

kinematic viscosity Density of samples to be entered
Temperature measurement

function

Standard temperature probe interface (optional temperature probe)
Automatic scanning function Automatically scan and recommend the preferred combination of rotor and rotation speed
Maximum measurement range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
Self-built Measuring

Procedures

Up to 30 groups (including rotor, speed, temperature, time, etc.)
Preservation of

measurements

Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear

stress, time, density, kinematic viscosity, etc.)

put a seal on Data, curve can be printed (standard print interface, need to buy printer)
data output interface USB: can insert U disk and copy data directly

RS232: Connect Computer

thermostatic components Selections (including various viscometer special thermostatic tank, thermostatic cup,

temperature control device, heating furnace)

working power supply Wide voltage operation (110 V/60 Hz or 220 V/50 Hz)
outline dimension 300 × 300 × 450(mm)

 

model LVDV-1T HADV-1T HBDV-1T
Control / display mode 5-inch color touch screen
speed(r/min) 0.3–100 infinitely variable speed , a total of 998 speed options
measuring range

 

Rotor R2-R7:100-13M

URL: 6.4 – 1K

Rotor 21: 50-167K

Rotor 27: 250-834K

Rotor 2: 500-1.7M

Rotor 29: 1K-3.3M

Rotor R2-R7:200–26M

URL: 12.8 – 1K

Rotor 21: 100-333K

Rotor 27: 500-1.7K

Rotor 28; 1K-3.3M

Rotor 29: 2K-6.6M

Rotor R2-R7:800-104M

URL: 51.2 – 2K

Rotor 21: 400-1.3M

Rotor 27: 2K-6.7M

Rotor 28: 4K-13.3M

Rotor 29: 8K-26.6M

K = 1000; M = 1000000
rotor R2- R7(6, standard)

R1(apolegamy)

Enhanced ultra-low viscosity adapter ULR (optional)

Small sample adapters (rotor 21,27,28,29)(optional))

Sample dosage Rotor R1-R7: 500ml

ULR: 21ml

Rotor 21: 7.8ml

Rotor 27: 11.3ml

Rotor 28: 12.6ml

Rotor 29: 11.5ml

measurement erro ±1%
repetitive error ±0.5%
Showing the shear response /

shear rate

standard configuration
Timing function standard configuration
Real-time display

Viscosity curve

 

Time-viscosity curve

Temperature-viscosity curve (optional temperature probe)

(Optional data processing software shows shear rate and viscosity curves)

kinematic viscosity Density of samples to be entered
Temperature measurement

function

Standard temperature probe interface (optional temperature probe)
Automatic scanning function Automatically scan and recommend the preferred combination of rotor and rotation speed
Maximum measurement range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
Self-built Measuring

Procedures

Up to 30 groups (including rotor, speed, temperature, time, etc.)
Preservation of

measurements

Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear

stress, time, density, kinematic viscosity, etc.)

put a seal on Data, curve can be printed (standard print interface, need to buy printer)
data output interface USB: can insert U disk and copy data directly

RS232: Connect Computer

thermostatic components Selections (including various viscometer special thermostatic tank, thermostatic cup,

temperature control device, heating furnace)

working power supply Wide voltage operation (110 V/60 Hz or 220 V/50 Hz)
outline dimension 300 × 300 × 450(mm)

 

model LVDV-2T HADV-2T HBDV-2T
Control / display mode 5-inch color touch screen
speed(r/min) 0.1–200 infinitely variable speed , a total of 2000 speed options
measuring range

 

Rotor R2-R7:100-4000M

URL: 3.2 – 1K

Rotor 21: 25-500K

Rotor 27: 125-2.5M

Rotor 8:250-5M

Rotor 29: 500-10M

Rotor R2-R7:200–8000M

URL: 6.4 – 1K

Rotor 21: 50-1M

Rotor 27:250-5M

Rotor 28: 500-10M

Rotor 29: 1K-20M

Rotor R2-R7:800-32000M

URL: 25.6 – 2K

Rotor 21: 200-4M

Rotor 27: 1K-20M

Rotor 28: 2K-40M

Rotor 29: 4K-80M

K = 1000; M = 1000000
rotor R2- R7(6, standard)

R1(apolegamy)

Enhanced ultra-low viscosity adapter ULR (optional)

Small sample adapters (rotor 21,27,28,29)(optional))

Sample dosage Rotor R1-R7: 500ml

ULR: 21ml

Rotor 21: 7.8ml

Rotor 27: 11.3ml

Rotor 28: 12.6ml

Rotor 29: 11.5ml

measurement erro ±1%
repetitive error ±0.5%
Showing the shear response /

shear rate

standard configuration
Timing function standard configuration
Real-time display

Viscosity curve

 

Time-viscosity curve

Temperature-viscosity curve (optional temperature probe)

(Optional data processing software shows shear rate and viscosity curves)

kinematic viscosity Density of samples to be entered
Temperature measurement

function

Standard temperature probe interface (optional temperature probe)
Automatic scanning function Automatically scan and recommend the preferred combination of rotor and rotation speed
Maximum measurement range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
Self-built Measuring

Procedures

Up to 30 groups (including rotor, speed, temperature, time, etc.)
Preservation of

measurements

Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear

stress, time, density, kinematic viscosity, etc.)

put a seal on Data, curve can be printed (standard print interface, need to buy printer)
data output interface USB: can insert U disk and copy data directly

RS232: Connect Computer

thermostatic components Selections (including various viscometer special thermostatic tank, thermostatic cup,

temperature control device, heating furnace)

working power supply Wide voltage operation (110 V/60 Hz or 220 V/50 Hz)
outline dimension 300 × 300 × 450(mm)

From left to right: R1- to R7 disk rotor

1R1 Rotor

Sample viscosity below the lower limit of the range of each model,need to be equipped with R1 rotor

2.Enhanced ultra-low viscosity adapter(ULR)

Designed for low viscosity fluid measurement,there are two specifications for jacket type and non-jacket

type,with a minimum detection limit of 1cP,depending on the type of viscometer used

  1. Small sample adapters (rotors 21,27,28,29)

  1. Temperature Probe (Temperature Sensor)

Temperature Probe (Temperature Sensor)

Temperature measurement range:-20-300°C

Measurement accuracy:0.1°C

  1. Micro thermal printer

Direct connection with a viscometer

print data

Print curve

  1. Special constant temperature bath for viscometer

5.1 CH1006N

Temperature control range:

Room temperature plus 10 ℃ -100 ℃

Temperature control accuracy: 0.1 ℃

5.2 DC0506W

Temperature control range : -5 to 100 ℃

Temperature control accuracy : 0.1 ℃

  1. data-processing software

The rheological curves of shear rate and viscosity

can be displayed by setting the measuring

parameters of viscometer by computer.

 

Contact us

24/7 customer support for troubleshooting and inquiries.

+86 15591731311

sales@hzscientific.com