SSR series digital rotary viscometer
the ssr series digital rotary viscometer adopts coaxial cylinder structure,using small sample adapter,the sample quantity required for each measurement is very small,only 7ml-13ml(rotor 0 is 21ml),optional constant temperature water jacket with cycle,with constant temperature tank to control the sample under test.
the ssr series digital rotary viscometer adopts coaxial cylinder structure,using small sample adapter,the sample quantity required for each measurement is very small,only 7ml-13ml(rotor 0 is 21ml),optional constant temperature water jacket with cycle,with constant temperature tank to control the sample under test.The operation is very convenient and the measurement is accurate.very suitable for precious,rare sample measurement.
characteristic:
1.Timing measurement function
2.Coaxial cylinder structure
3.Using a spindle rotor,the sample size required for testing is very small
4.Two RS232 interfaces with direct connection to micro printer and computer
1.Detailed technical parameters of LV-SSR rotary viscometer:
model |
LV-SSR |
display mode |
digital display |
speed(r/min) |
0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100
Total 18 |
rotor |
18#,25#,31#,34# (standard configuration) |
measuring range |
3-1.6M (mPa﹒s) |
Sample size |
18# rotor:3 –10K; 7ml
25# rotor:480 –1.6M; 9ml 31# rotor:30 –100K; 10.5ml 34# rotor:60 –200K; 11ml |
measurement
error |
±3% (Newtonian liquid) |
repetitive error |
±1.5% (Newtonian liquid) |
output interface |
Two RS232 interfaces to connect printer and computer |
Temperature Probe
Interface |
standard configuration |
outline dimension |
300 × 300 × 450(mm) |
2.Detailed technical parameters of the RV-SSR/HA-SSR/HB-SSR rotary viscometer:
model | RV-SSR | HV-SSR | HB-SSR |
display mode | digital display | ||
speed(r/min) | 0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100
Total 18 |
||
rotor | 21#、27#、28#、29# (standard configuration)
|
||
measuring range | 50 – 2M
21# rotor:50-100K 27# rotor:250-500K 28# rotor:500-1M 29# rotor:1K-2M |
100 – 4M
21# roto:100-200K 27# roto:500-1M 28# roto:1K-2M 29# roto:2K-4M |
400 – 16M
21# roto:400-800K 27# roto:2K-4M 28# roto:4K-8M 29# roto:8K-16M |
Sample size | 21# roto: 7.8ml
27# roto: 11.3ml 28# roto: 12.6ml 29# roto: 11.5ml |
||
Measurement error | ±3% (Newtonian liquid) | ||
repetitive error | ±1.5% (Newtonian liquid) | ||
output interface | Two RS232 interfaces to connect printer and computer | ||
Temperature Probe Interface | standard configuration | ||
outline dimension | 300 × 300 × 450(mm) |