M310T Multi-parameter Analyzer

M500T-A Multi-parameter Analyzer
M500T Multi-parameter Analyzer
Intelligent operation system provides features including user management,calibration management,method management,data management and etc.

GENERAL FEATURES
●Color High contrast LCD touchscreen,7.0 inches.
●Intelligent operation system provides features including user management,calibration management,method management,data management and etc.
●Multi-reading feature allows auto-read,timed-read and continuous-read.
●Automatic/Manual temperature compensation ensures accurate results.
●Data Storage 1000 sets for each parameter(GLP-compliant).
●Data analysis feature helps user review,compare and recalculate results.
●Support for USB or RS-232 communication.
●Reset feature automatically resumes all settings back to factory default options.
●IP54 waterproof.
pH
●1-6 points calibration with Standard Recognition.
●Selectable pH buffer groups,including DIN,NIST,USA,MERK,JIS,GB.
●Support for pH standard group customization.
●Automatic electrode diagnosis with pH slope and offset display.
Ion
●1-6 points calibration.
●Selectable measurement unit,includingμg/L,mg/L,g/L,mmol/L,pX,ppm,ppb,etc.
●Multi-measurement modes are supported,including Direct Reading mode,Standard Addition mode,Sample Addition mode and GRAN mode.
●Over 10 methods are built-in,including F-,Cl-,Br-,I-,NO3-,BF4-,NH4+,K+,Na+,Ca2+,Cu2+,Pb2+,Ag+and etc.,user-defined method is supported.
Conductivity
●1-3 points calibration with Standard Recognition.
●Settable parameters,including cell constant,temperature compensation coefficient and TDS factor.
●Temperature compensation type(none,linear,pure water).
DO
●Support for air-saturated water or zero oxygen calibration.
●Auto barometric pressure compensation
●Manual Salinity Factor Correction
●Selectable pressure unit,including kPa,mbar,Torr,Atm.
| Model | M500T | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01pH | |
| Accuracy | ± 0.002 pH | |
| Calibration Points | Up to 6 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
| Slope Limit | Yes | |
|
mV/ORP |
Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1mV | |
| Accuracy | reading whichever is greater | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01,0.001pX | |
| Accuracy | ± 0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1.000e-9 to 9.999e+9 |
| Units | mol/L, mmol/L, g/L, mg/L, μ g/L, ppm, ppb | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ± 0.3% | |
| Calibration Points | Up to 6 | |
| Conductivity | Range | 0.000 μ S/cm to 2000 mS/cm |
| Resolution | 0.001 μ S/cm minimum, various with range selection | |
| Accuracy | ± 0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Calibration Reminder | Yes | |
| Standard Recognition | 10 μ S/cm, 84 μ S/cm, 500 μ S/cm, 1413 μ S/cm, 12.88 mS/cm; 146.5 μ S/
cm, 1408 μ S/cm, 12.85mS/cm, 111.3mS/cm |
|
| Resistivity | Range | 5.00 Ω ·cm~100.0 M Ω ·cm |
| Resolution | 0.01 Ω ·cm minimum | |
| Accuracy | ± 0.5% FS | |
| TDS | Range | 0.000~1000 ppt |
| Resolution | 0.001 ppm minimum, changed with range | |
| Accuracy | ± 0.5% FS | |
| Salinity | Type | NaCl |
| Range | 0.0 ~ 80.0 ppt | |
| Resolution | 0.1ppt | |
| Accuracy | ± 1ppt | |
| Dissolved
Oxygen Concentration -Polarographic |
Range | 0.00 to 99.99 ppm |
| Resolution | 0.01 ppm | |
| Accuracy | ± 0.10 ppm | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| % Saturation -Polaro
graphic |
Range | (0.0 to 600.0)% |
| Resolution | 0.1% | |
| Accuracy | ± 2.0% | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ± 0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC, scanner, |
| RS 232 | printer, auto-sampler | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Power | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 220 × 195 × 68 mm | |
| Weight | 950g (2.09 lb) | |