M310F-A Multi-parameter Analyzer

Automatic/Manual temperature compensation ensures accurate results.

GENERAL FEATURES

●LCD display screen,3.5 inches.

●Multi-reading feature allows auto-read,timed-read and continuous-read.

●Automatic/Manual temperature compensation ensures accurate results.

●Auto-hold feature senses and locks the measurement endpoint.

●Data capacity of up to 500 sets for each parameter(GLP-compliant).

●Support for USB communication.

●Auto-power off feature effectively extends the battery service life.

●Reset feature automatically resumes all settings back to factory default options.

●IP65 waterproof.The portable meter is suitable for fields measurements and out door measurements.

pH

●1-5 points calibration with Standard Recognition.

●Selectable pH buffer groups,including NIST,DIN,GB,USA.

●Automatic electrode diagnosis with pH slope and offset display.

Ion

●1-5 points calibration.

●Selectable measurement unit,includingμg/L,mg/L,g/L,mmol/L,pX,ppm,ppb,etc.

●Multi-measurement modes are supported,including Direct Reading mode,Standard Addition mode,Sample Addition mode and GRAN mode.

●Over 10 methods are built-in,including F-,Cl-,Br-,I-,NO3-,BF4-,NH4+,K+,Na+,Ca2+,Cu2+,Pb2+,Ag+and etc.,user-defined method is supported.

Conductivity

●1-3 points calibration with Standard Recognition.

●Settable parameters,including cell constant,temperature compensation coefficient and TDS factor.

●Temperature compensation type(none,linear,pure water).

DO

●Support for air-saturated water or zero oxygen calibration.

●Auto barometric pressure compensation

●Manual Salinity Factor Correction

●Selectable pressure unit,including kPa,mbar,Torr,Atm.

Model M310F-A
Parameters pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)

 

pH Range -2.000 to 20.000 pH
  Resolution 0.1, 0.01pH
  Accuracy ± 0.001 pH
  Calibration Points Up to 5
  Standard Customization Yes
  Standard Recognition NIST, GB, USA and DIN buffers
  Slope Limit Yes
mV/ORP Range -2000.00 to 2000.00 mV
  Resolution 0.1mV
  Accuracy ± 0.3 mV or ± 0.1%
pX Range -2.000 to 20.000 pX
  Resolution 0.1, 0.01pX
  Accuracy ± 0.001 pX
  Calibration Points Up to 5
ISE Range 1.000e-9 to 9.999e+9
  Units mol/L, mmol/L, g/L, mg/L, μ g/L, ppm, ppb
  Resolution Up to 4 significant digits
  Accuracy ± 0.5%
  Calibration Points Up to 5
Conductivity Range 0.000 μ S/cm to 500 mS/cm
  Resolution 0.001 μ S/cm minimum, various with range selection
  Accuracy ± 0.1% FS
  Reference Temperature 20, 25 ºC
  Calibration Points Up to 3
  Standard Recognition 84 μ S/cm, 1413 μ S/cm, 12.88mS/cm
Resistivity Range 5.00 Ω ·cm~20.0 M Ω ·cm
  Resolution 0.01 Ω ·cm minimum
  Accuracy ± 0.1% FS
TDS Range 0.000~300 ppt
  Resolution 0.001 ppm minimum, changed with range
  Accuracy ± 0.1% FS
 

Salinity

Range 0.0 ~ 80.0 ppt
  Resolution 0.1ppt
  Accuracy ± 2ppt
  Accuracy ± 2.0%
 

Temperature

Range -5 to 110 ºC, 23 to 230 ºF
  Unit ºC, ºF
  Resolution 0.1
  Accuracy ± 0.2
Measurement Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
  Reading Prompts Reading, Stable, Locked
  Temp. Compensation ATC, MTC
Data management Data Storage 500 results each
  GLP Features Yes
Inputs pH Electrode BNC(Q9)
  DO with Temp. Probe 4-pin aviation connector
  Conductivity with Temp. Probe 5-pin aviation connector
Outputs USB  PC,printer
 

Display options

Backlight Yes
  Auto Shutdown 300, 600, 1200, 1800, 3600 sec., off
  IP Rating IP65
  Date and Time Yes
General Power Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output
  Dimensions 80 × 225 × 35 mm
  Weight 400g (0.88 lb)

Contact us

24/7 customer support for troubleshooting and inquiries.

+86 15591731311

sales@hzscientific.com