M600L Multi-parameter Analyzer
Intelligent operation system provides features including user management,calibration management,method management,data management and etc.
GENERAL FEATURES
●Color High contrast LCD touchscreen,7.0 inches.
●Intelligent operation system provides features including user management,calibration management,method management,data management and etc.
●Multi-reading feature allows auto-read,timed-read and continuous-read.
●Automatic/Manual temperature compensation ensures accurate results.
●Data Storage 1000 sets for each parameter(GLP-compliant).
●Data analysis feature helps user review,compare and recalculate results.
●Support for USB or RS-232 communication.
●Reset feature automatically resumes all settings back to factory default options.
●IP54 waterproof.
●Support for three modules,namely pH/ISE module,conductivity module and dissolved oxygen module.
●Select from three modules to customize the four channels your way.
●Four channels can be configured in any combination.
pH
●1-6 points calibration with Standard Recognition.
●Selectable pH buffer groups,including NIST,DIN,GB.
●Support for pH standard group customization.
●Automatic electrode diagnosis with pH slope and offset display.
Ion
●1-6 points calibration
●Selectable measurement unit,includingμg/L,mg/L,g/L,mmol/L,pX,etc.
●Multi-measurement modes are supported,including Direct Reading mode,Standard Addition mode,Sample Addition mode and GRAN mode.
●Over 10 methods are built-in,including F-,Cl-,Br-,I-,NO3-,BF4-,NH4+,K+,Na+,Ca2+,Cu2+,Pb2+,Ag+and etc.,user-defined method is supported.
Conductivity
●1-5 points calibration with Standard Recognition.
●Settable parameters,including cell constant,reference temperature(5/10/15/18/20/25°C),temperature compensation coefficient and TDS factor.
●Temperature compensation type(none,linear,pure water).
DO
●Support for air-saturated water or zero oxygen calibration.
●Auto barometric pressure compensation.
●Manual Salinity Factor Correction.
●Selectable pressure unit,including kPa,mbar,Torr,Atm.
Model | M600L | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ± 0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ± 0.03%FS | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1~2 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ± 0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1.000e-9 to 9.999e+9 |
Units | mol/L, mmol/L, g/L, mg/L, μ g/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ± 0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μ S/cm to 3000 mS/cm |
Resolution | 0.001 μ S/cm minimum, various with range selection | |
Accuracy | ± 0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Standard Recognition | 146.5 μ S/cm, 1408 μ S/cm, 12.85mS/cm, 111.3mS/cm | |
Resistivity | Range | 5.00 Ω ·cm~100.0 M Ω ·cm |
Resolution | 0.01 Ω ·cm minimum | |
Accuracy | ± 0.5% FS | |
TDS | Range | 0.000 mg/L~1000 g/L |
Resolution | 0.001ppm minimum, changed with range | |
Accuracy | ± 0.5% FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.01% | |
Accuracy | ± 0.1% | |
Dissolved | Range | 0.00 to 99.99 mg/L |
Oxygen Concentration – Polarographic | Resolution | 0.01 mg/L |
Accuracy | ± 0.1 mg/L | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
% Saturation -Polaro- graphic | Range | (0.0 to 600)% |
Resolution | 0.10% | |
Accuracy | ± 2.0% | |
Temperature | Range | -5 to 130 ºC |
Unit | ºC | |
Resolution | 0.1 | |
Accuracy | ± 0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 6-pin Mini-DIN | |
Conductivity with Temp. Probe | 8-pin Mini-DIN | |
Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Power | AC Adapter, 100-240V AC input, DC24V output |
Dimensions | 280 × 280 × 130 mm | |
Weight | 2500g (5.51 lb) |